Tag Archives: brocade

Comparing different technologies

OK, let me make one this clear, and most of you know this already, I’m not a fan of FCoE and I wrote numerous articles around this topic. I work for a vendor especially focusing on storage connectivity in a engineering support role. Basically it means I need to know this stuff. When I see people struggling with storage from a connectivity perspective and I come to a point I either meet these people in person or have them on the phone I’m pretty often absolutely flabbergasted around the lack of fairly basic knowledge of Fibre-Channel. The basics of checking port and link errors, the generic concept of flow control and operational management is very often on a pretty low level. Don’t get me wrong, I’m not accusing anyone of being stupid however it turns out that education and self-study w.r.t. storage is not seen as a critical item on the day-to-day IT department shopping list and focus is more leaning towards networking, operating systems and applications.

If, however, your sole job is storage and you are tasked to provide a study between two different sorts of technology both touching the same subject and you’re able to screw up the way the Evaluator Group has done last week I seriously doubt the credibility of such an organization.

Continue reading

Dynamic Load Sharing (DLS) and In Order Delivery (IOD)

The storage world has always been predictable (from a technical side that is. :-)) This means that data coming from an application through server and traversing a multitude of connected devices to a spindle (in whatever form or shape) takes the logically shortest, fasted and best available route. These routes are calculated based on a protocol called FSPF. (Fabric Shortest Path First) and is somewhat analogous to OSPF in the networking world.

Both OSPF and FSPF are based on Dijkstra’s algorithm of mathematically calculating the shortest path between any two given points. When you fire up Google maps and use the “Directions” option to get a route from A to B the same algorithm is used. Obviously you can adjust the paths between those two points to either include or exclude certain criteria like distance, speed etc. on which you let loose the Dijkstra calculations. To go back to storage the results of the calculations in addition to secondary criteria (zoning, route-costs etc.) determines the routes that are programmed into the ASICs or cross-bar switches. So what does this have to do with load-sharing and delivery ordering??

Continue reading

Brocade HCM on Windows does not start

Due to an (yet) unknown cause it seems the webcomponent of the Host Connectivity Manager in Brocade HCM (the agent part of the adapter driver) has placed an incorrect value in the abyss (webserver) configuration file (abyss.conf). The “ServerRoot” entry points to C;\hbaagent whereas it should’ve pointed to “<install dir>\BROCADE\Adapter\driver\util\hbaagent”.

The issue happened in this case on a Windows 2008 R2 64bit SP1 EE server. If you rectify the entry the HCM agent will most likely start and your problem is solved.

Hope this helps.

Erwin

Brocade AAA authentication problem

Do you get nuts about these user-names and passwords you need to remember across all these different systems, platforms and applications. LDAP or RADIUS is your friend. When you make a mistake however it can also be you biggest enemy.

Brocade offers you the option to hook up a switch to LDAP or RADIUS for central authentication. (only Authentication).
An incorrectly configured LDAP or RADIUS configuration on a Brocade switch may lock out network access. This applies to telnet, ssh, webtools and SMI-S.

When AAA configuration is done via the CLI it is very important to specify the correct parameters and specifically the double quotation marks. If ldap is configured with the local database as fall-back the command would be aaaconfig –authspec “ldap;local”. If the quotation marks are omitted the semicolon will be interpreted as a command-line separator. (These commands are executed in a so called restricted Linux bash shell and as such have to abide the rules according to this shell) In essence two commands will then be executed separately.

aaaconfig –authspec ldap
local

The first command will succeed and change the authentication method to LDAP and will immediately logout all logged in users. If LDAP is incorrectly configured all authentication requests will fail and network access is not possible.

To fix this you will need to attach a serial cable to the switch (or Active CP)

  1. Connect the serial cable to the switch serial management port. (On a blade system like DCXX or 48000 connect to the active CP)
  2. Login with either root or admin account. (Console access is still allowed).
  3. Modify the AAA configuration with the command aaaconfig –authspec “ldap;local”.
  4. Depending on the ldap authentication timeout settings the login will fall back to the local user-database for authentication.

Cheers,
Erwin

5-minute initial troubleshooting on Brocade equipment

Very often I get involved in cases whereby a massive amount of host logs, array dumps, FC and IP traces are taken which could easily add up to many gigabytes of data. This is then accompanied by a very synoptic problem description such as “I have a problem with my host, can you check?”.
I’m sure the intention is good to provide us all the data but the problem is the lack of the details around the problem. We do require a detailed explanation of what the problem is, when did it occur or is it still ongoing?

There are also things you can do yourself before opening a support ticket. In many occasions you’ll find that the feedback you get from us in 10 minutes results in either the problem being fixed or a simple workaround has made your problem creating less of an impact. Further troubleshooting can then be done in a somewhat less stressful time frame.

This example provides some bullet points what you can do on a Brocade platform. (Mainly since many of the problems I see are related to fabric issues and my job is primarily focused on storage networking.)

First of all take a look at the over health of the switch:

switchstatusshow
Provides an overview of the general components of the switch. These all need to show up HEALTHY and not (as shown here) as “Marginal”

Sydney_ILAB_DCX-4S_LS128:FID128:admin> switchstatusshow
Switch Health Report Report time: 06/20/2013 06:19:17 AM
Switch Name: Sydney_ILAB_DCX-4S_LS128
IP address: 10.XXX.XXX.XXX
SwitchState: MARGINAL
Duration: 214:29

Power supplies monitor MARGINAL
Temperatures monitor HEALTHY
Fans monitor HEALTHY
WWN servers monitor HEALTHY
CP monitor HEALTHY
Blades monitor HEALTHY
Core Blades monitor HEALTHY
Flash monitor HEALTHY
Marginal ports monitor HEALTHY
Faulty ports monitor HEALTHY
Missing SFPs monitor HEALTHY
Error ports monitor HEALTHY

All ports are healthy

switchshow
Provides a general overview of logical switch status (no physical components) plus a list of ports and their status.

  • The switchState should alway be online.
  • The switchDomain should have a unique ID in the fabric.
  • If zoning is configured it should be in the “ON” state.

As for the ports connected these should all be “Online” for connected and operational ports. If you see ports showing “No_Sync” whereby the port is not disabled there is likely a cable or SFP/HBA problem.

If you have configured FabricWatch to enable portfencing you’ll see indications like here with port 75

Obviously for any port to work it should be enabled.

Sydney_ILAB_DCX-4S_LS128:FID128:admin> switchshow
switchName: Sydney_ILAB_DCX-4S_LS128
switchType: 77.3
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 143
switchId: fffc8f
switchWwn: 10:00:00:05:1e:52:af:00
zoning: ON (Brocade)
switchBeacon: OFF
FC Router: OFF
Fabric Name: FID 128
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Address Mode 0]

Index Slot Port Address Media Speed State Proto
============================================================
0 1 0 8f0000 id 4G Online FC E-Port 10:00:00:05:1e:36:02:bc “BR48000_1_IP146” (downstream)(Trunk master)
1 1 1 8f0100 id N8 Online FC F-Port 50:06:0e:80:06:cf:28:59
2 1 2 8f0200 id N8 Online FC F-Port 50:06:0e:80:06:cf:28:79
3 1 3 8f0300 id N8 Online FC F-Port 50:06:0e:80:06:cf:28:39
4 1 4 8f0400 id 4G No_Sync FC Disabled (Persistent)
5 1 5 8f0500 id N2 Online FC F-Port 50:06:0e:80:14:39:3c:15
6 1 6 8f0600 id 4G No_Sync FC Disabled (Persistent)
7 1 7 8f0700 id 4G No_Sync FC Disabled (Persistent)
8 1 8 8f0800 id N8 Online FC F-Port 50:06:0e:80:13:27:36:30
75 2 11 8f4b00 id N8 No_Sync FC Disabled (FOP Port State Change threshold exceeded)
76 2 12 8f4c00 id N4 No_Light FC Disabled (Persistent)

sfpshow slot/port
One of the most important pieces of a link irrespective of mode and distance is the SFP. On newer hardware and software it provides a lot of info on the overall health of the link.

With older FOS codes there could have been a discrepancy of what was displayed in this output as to what actually was plugged in the port. The reason was that the SFP’s get polled so every now and then for status and update information. If a port was persistent disabled it didn’t update at all so in theory you plug in another SFP but sfpshow would still display the old info. With FOS 7.0.1 and up this has been corrected and you can also see the latest polling time per SFP now.

The question we often get is: “What should these values be?”. The answer is “It depends”. As you can imagine a shortwave 4G SFP required less amps then a longwave 100KM SFP so in essence the SFP specs should be consulted. As a ROT you can say that signal quality depends ont he TX power value minus the link-loss budget. The result should be withing the RX Power specifications of the receiving SFP.

Also check the Current and Voltage of the SFP. If an SFP is broken the indication is often it draws no power at all and you’ll see these two dropping to zero.

Sydney_ILAB_DCX-4S_LS128:FID128:admin> sfpshow 1/1
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 540c404000000000 2,4,8_Gbps M5,M6 sw Short_dist
Encoding: 1 8B10B
Baud Rate: 85 (units 100 megabaud)
Length 9u: 0 (units km)
Length 9u: 0 (units 100 meters)
Length 50u (OM2): 5 (units 10 meters)
Length 50u (OM3): 0 (units 10 meters)
Length 62.5u:2 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000012-01
Vendor Rev: A
Wavelength: 850 (units nm)
Options: 003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: UAF110480000NYP
Date Code: 101125
DD Type: 0x68
Enh Options: 0xfa
Status/Ctrl: 0x80
Alarm flags[0,1] = 0x5, 0x0
Warn Flags[0,1] = 0x5, 0x0
Alarm Warn
low high low high
Temperature: 25 Centigrade -10 90 -5 85
Current: 6.322 mAmps 1.000 17.000 2.000 14.000
Voltage: 3290.2 mVolts 2900.0 3700.0 3000.0 3600.0
RX Power: -3.2 dBm (476.2uW) 10.0 uW 1258.9 uW 15.8 uW 1000.0 uW
TX Power: -3.3 dBm (472.9 uW) 125.9 uW 631.0 uW 158.5 uW 562.3 uW

State transitions: 1
Last poll time: 06-20-2013 EST Thu 06:48:28

porterrshow
For link state counters this is the most useful command in the switch however there is a perception that this command provides a “silver” bullet to solve port and link issues but that is not the case. Basically it provides a snapshot of the content of the LESB (Link Error Status Block) of a port at that particular point in time. It does not tell us when these counters have accumulated and over which time frame. So in order to create a sensible picture of the statuses of the ports we need a baseline. This baseline can be created to reset all counters and start from zero. To do this issue the “statsclear” command on the cli.

There are 7 columns you should pay attention to from a physical perspective.

enc_in – Encoding errors inside frames. These are errors that happen on the FC1 with encoding 8 to 10 bits and back or, with 10G and 16G FC from 64 bits to 66 and back. Since these happen on the bits that are part of a data frame that are counted in this column.

crc_err – An enc_in error might lead to a CRC error however this column shows frames that have been market as invalid frames because of this crc-error earlier in the datapath. According to FC specifications it is up to the implementation of the programmer if he wants to discard the frame right away or mark it as invalid and send it to the destination anyway. There are pro’s and con’s on both scenarios. So basically if you see crc_err in this column it means the port has received a frame with an incorrect crc but this occurred further upstream.

crc_g_eof – This column is the same as crc_err however the incoming frames are NOT marked as invalid. If you see these most often the enc_in counter increases as well but not necessarily. If the enc_in and/or enc_out column increases as well there is a physical link issue which could be resolved by cleaning connectors, replacing a cable or (in rare cases) replacing the SFP and/or HBA. If the enc_in and enc_out columns do NOT increase there is an issue between the SERDES chip and the SFP which causes the CRC to mismatch the frame. This is a firmware issue which could be resolved by upgrading to the latest FOS code. There are a couple of defects listed to track these.

enc_out – Similar to enc_in this is the same encoding error however this error was outside normal frame boundaries i.e. no host IO frame was impacted. This may seem harmless however be aware that a lot of primitive signals and sequences travel in between normal data frame which are paramount for fibre-channel operations. Especially primitives which regulate credit flow. (R_RDY and VC_RDY) and signal clock synchronization are important. If this column increases on any port you’ll likely run into performance problems sooner or later or you will see a problem with link stability and sync-errors (see below).

Link_Fail – This means a port has received a NOS (Not Operational) primitive from the remote side and it needs to change the port operational state to LF1 (Link Fail 1) after which the recovery sequence needs to commence. (See the FC-FS standards specification for that)

Loss_Sync – Loss of synchronization. The transmitter and receiver side of the link maintain a clock synchronization based on primitive signals which start with a certain bit pattern (K28.5). If the receiver is not able to sync its baud-rate to the rate where it can distinguish between these primitives it will lose sync and hence it cannot determine when a data frame starts.

Loss_Sig – Loss of Signal. This column shows a drop of light i.e. no light (or insufficient RX power) is observed for over 100ms after which the port will go into a non-active state. This counter increases often when the link-loss budget is overdrawn. If, for instance, a TX side sends out light with -4db and the receiver lower sensitivity threshold is -12 db. If the quality of the cable deteriorates the signal to a value lower than that threshold, you will see the port bounce very often and this counter increases. Another culprit is often unclean connectors, patch-panels and badly made fibre splices. These ports should be shut down immediately and the cabling plant be checked. Replacing cables and/or bypassing patch-panels is often a quick way to find out where the problem is.

The other columns are more related to protocol issues and/or performance problems which could be the result of a physical problem but not be a cause. In short look at these 7 columns mentioned above and check if no port increases a value.

============================================
too_short/too_long – indicates a protocol error where SOF or EOF are observed too soon or too late. These two columns rarely increase.

bad_eof – Bad End-of-Frame. This column indicates an issue where the sender has observed and abnormality in a frame or it’s transceiver whilst the frameheader and portions of the payload where already send to its destination. The only way for a transceiver to notify the destination is to invalidate the frame. It truncates the frame and add an EOFni or EOFa to the end. This signals the destination that the frame is corrupt and should be discarded.

F_Rjt and F_Bsy are often seen in Ficon environments where control frames could not be processes in time or are rejected based on fabric configuration or fabric status.

c3timout (tx/rx) – These are counters which indicate that a port is not able to forward a frame in time to it’s destination. These either show a problem downstream of this port (tx) or a problem on this port where it has received a frame meant to be forwarded to another port inside the sames switch. (rx). Frames are ALWAYS discarded at the RX side (since that’s where the buffers hold the frame). The tx column is an aggregate of all rx ports that needs to send frames via this port according to the routing tables created by FSPF.

pcs_err – Physical Coding Sublayer – These values represent encoding errors on 16G platforms and above. Since 16G speeds have changed to 64/66 bits encoding/decoding there is a separate control structure that takes care of this.

As a best practise is it wise to keep a trace of these port errors and create a new baseline every week. This allows you to quickly identify errors and solve these before they can become an problem with an elongated resolution time. Make sure you do this fabric-wide to maintain consistency across all switches in that fabric.

Sydney_ILAB_DCX-4S_LS128:FID128:admin> porterrshow
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err
0: 100.1m 53.4m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1: 466.6k 154.5k 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
2: 476.9k 973.7k 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3: 474.2k 155.0k 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Make sure that all of these physical issues are solved first. No software can compensate for hardware problems and all OEM support organizations will give you this task anyway before commencing on the issue.

In one of my previous articles I wrote about problems, the cause and the resolution of physical errors. You can find it over here

Regards,
Erwin

Brocade MAPS – Improvement in usability, reduction in functionality

(This post is mostly obsolete to to the many improvements in FSO 7.3, 7.4 and beyond. I would seriously urge you to consider using MAPS. See here)

With FOS 7.2.0 Brocade introduced MAPS (no not the google version). It’s a new functionality that is intended to replace and improve the usability of Fabric Watch. As I wrote earlier here Fabric Watch has always been one of the best pieces of functionality in FOS and I’ve used it ever since they introduced it al the way back in FOS 3.x or 4.x I think it was (Yes I’m that old). FW enables you to create thresholds on numerous elements in a switch or fabric. This goes from port-errors to environmental problems like elevated temperature and other hardware problems. In addition individual actions can be configured like sending out emails, snmp traps or yet even better, disable ports in case it can have or already has significant ramifications and follow-up issues in a fabric.

The biggest problem with FW always has been the sheer amount of options, menu items and CLI parameters which caused it a to be a challenge to configure it to such an extend it became useful. It is like using VI (the text editor, not the company) for the first time, you’d rather have a root canal and endoscopy at the same time but as soon as you have the hang of it you discover the sheer power of this tool and the amount of proactive management, alerts and other options will make you SAN almost bullet proof (I’m not saying monkey-proof :-)). This is also the reason that FW is either not used or configured with incorrect parameters so that it will spit out too many or too few notifications. Once again I would like to stress the importance of this great tool and the ROI will certainly double both in time and money.

So then why MAPS. Remember that Brocade is also fairly active in the networking side of the fence with the acquisition of Foundry back in 2008 and more recently Vyatta to obtain a software based networking virtualization stack. With the introduction of their FabricVision roadmap you can see that overall management needs to be synchronised and consolidated. Having 4 different hardware and software platforms (SAN, Ethernet, VCS/Converged and virtual) means this is a fairly daunting task. Brocade Network Advisor has become the management framework to handle all this albeit it is still a work in progress.

MAPS simplifies the overall management of the RAS features in FOS to more align with the capabilities across these platforms. Secondly, the number of support cases related to physical issues has increased significantly ever since the FC speeds and feeds went to 8G and 16G. 8G and 16G did not only require an update on switches and HBA’s but also the requirements on cable quality changed. OM2 is no longer sufficient on these speeds. OM3 and OM4 is required for the respective connection speeds from end-to-end including patch-panels, connectors etc. Since this physical aspect of many infrastructures is not updated the increase in problems observed are almost linear proportional to the degraded quality of the physical cable plant. I’ve seen many examples whereby an 8G port was unable to connect and just by reducing the speed back to 4G it did not observe any issues. MAPS cannot help you with re-cabling your plant but it can help stay on top of issues that might surface.

What I don’t like about MAPS is that is has significantly reduced the granularity of elements, objects and values you can configure. This might not suit every environment so conflicts of interest might become a problem. Also some settings may be converted from FW but you can’t change it. This is especially annoying if you made an incorrect configuration, converted to MAPS and all of a sudden you get hit by a gazillion alerts which you then cannot modify. Also very annoying is the issue that you cannot configure different email notifications to different people. If you encounter a temperature problem you might want to let the operators of the data-centre know of this issue but when a port observes a protocol problem they don’t need to know. Currently your can’t change that.

I do think MAPS is currently a work in progress as previously mentioned and thus I cannot recommend to migrate to MAPS just yet. Maybe in FOS 7.3 or even 8 it has matured enough to fully replace Fabric Watch. If you have licenses for Fabric Watch I would certainly recommend investing some time in this and configure it according to your needs. The FW Admin guide is a great resource and it will certainly increase the stability of your fabric.

Cheers,
Erwin

UPDATE: Brocade has pulled FOS 7.2.0 due to the fact it introduced so many new defects that it became more pretty dangerous to even think about running this version. As usual the x.x.0 releases should be avoided.